NEU GRAND LIBRARY
Opening Hours: Monday-Saturday, 08:00-20:00 | E-mail: library@neu.edu.tr
 

You are not logged in Show Basket
  Home     Advanced Search     Back  
  Brief display     MARC Display     Reserve  
The utility of handheld metal detector in confirming metallic foreign body ingestion in the pediatric emergency department (Saz, Eylem Ulas.)
Bibliographical information (record 264799)
Help
The utility of handheld metal detector in confirming metallic foreign body ingestion in the pediatric emergency department
Author:
Saz, Eylem Ulas. Search Author in Amazon Books

Publisher:
Ankara :
Edition:
2010.
Classification:
WI 140
URL:

http://library.neu.edu.tr:2048/login?url=http://dx.doi.org/10.4318/tjg.2010.0071
Detailed notes
    - Background/aims: We aimed to identify the presence of ingested metallic foreign bodies with handheld metal detector in the pediatric population. Methods: All children (n=40) known or suspected to have ingested a MFB and who presented to the Emergency Department of the Children's Hospital of Ege University were prospectively ascertained. All patients underwent both radiographic evaluation and handheld metal detector scanning of the chest and abdomen on their presentation. In the present prospective study, we compared handheld metal detector scanning with plain radiography. Results: The end point of the study compared metallic foreign body findings with handheld metal detector vs radiological findings during an eight-month period. Forty subjects with possible metallic foreign body ingestion were enrolled into the study. The principle investigator scanned all subjects. Disease was defined by the presence of a foreign body in the gastrointestinal tract on radiograph. Radiographically, 35 foreign bodies were found, and handheld metal detector revealed 31 of them. The sensitivity of handheld metal detector was 88.6% (95% confidence interval [CV: 72.1%-96.5%), specificity 100% (95% CI: 61.8%-100%), positive predictive value (PPV) 100% (95% CI: 85.8%-100%), and negative predictive value 55.5% (95% CI: 34.3%-84.6%). Handheld metal detector revealed that 2 metallic foreign bodies (1 pushpin, I coin) were localized to the chest, which was confirmed by radiography, and urgent removal was performed with endoscopy. Conclusions: Handheld metal detector scanning is an accurate, inexpensive, radiation-free screening tool and should be used for evaluation of patients suspected of ingesting metallic foreign bodies.
Related links
Items (1)
Barcode
Status
Library
Section
EOL-201
Item available
NEU Grand LibraryOnline (WI 140 .U85 2010)
Online electronic

NEAR EAST UNIVERSITY GRAND LIBRARY +90 (392) 223 64 64 Ext:5536. Near East Boulevard, Nicosia, TRNC
This software is developed by NEU Library and it is based on Koha OSS
conforms to MARC21 library data transfer rules.